Home | Products | Fume Arm Filtration Unit

Fume Arm Filtration

OVERVIEW


Our Fume Arm Filtration (FAF) units combine a high-quality fume extraction arm with a compact, powerful filter kit—giving you a complete plug-and-play source capture solution. These systems are ideal for welding labs, small shops or facilities that don’t need a full-size dust collector. Each unit includes an industrial fan, MERV-15 filter and fume extraction arm with spark protector to effectively remove harmful fumes at the source. Easy to install and even easier to maintain, FAF units are a smart, space-saving solution for cleaner, safer air.

  • IAP Extraction Fume Arm Filtration
    Write your caption here

Fume Arm Filtration

  • Industrial Strength
  • Versatile Design
  • Smooth Tube Construction
  • External Joints and Support
  • Hood and Tube Grab Handles
  • Air Diverter in the Hood
  • Standard Damper in the Tube
  • FR Nanofiber Filter, Merv 15
  • 18″ Reverse Flow Disposable Filter
REQUEST PRICING

FUME ARM FILTRATION MODELS

SKU Fume Arm Size Fan HP
FAF-0405 4" x 5' 1HP, 120V/1P
FAF-0408 4" x 8' 1HP, 120V/1P
FAF-0607 6" x 7' 1.5HP, 120V/1P *
FAF-0610 6" x 10' 1.5HP, 120V/1P *
FAF-0614 6" x 14' 1.5HP, 120V/1P *
FAF-0807 8" x 7' 2HP, 120V/1P *
FAF-0810 8" x 10' 2HP, 120V/1P *
FAF-0814 8' x 14' 2HP, 120V/1P *

* Can be wired 240V/1P


FUME ARM FILTRATION OPTIONS

HEPA Filter Media
FAF-F-1HP-HEPA-S HEPA with prefilter
FAF-F-1.5/2/3HP-HEPA-S HEPA with prefilter
Starter Motor SKU HP Voltage/Phase
MMS-1HP-120V/1 1 120V/1
MMS-2HP-120V/1 1.5 - 2 120V/1




Pair your IAP-Air Products extraction fume arm with a direct mount fan and filter assembly.  Fans are available in 1HP, 1.5HP, 2HP and 3HP.


Why Choose IAP fume Arm Filtration Units?

They are built for industrial welding fume extraction

IAP Fume Arm Filtration Units (FAF) are designed for industrial welding and fabrication environments where reliable source capture is essential. With heavy-duty fume arms and multiple configuration options, FAF provides a practical solution for capturing welding fumes directly at the source.


They are available in multiple fume arm sizes & lengths

FAF systems are available with 4", 6" and 8" fume arms in a variety of lengths, including 5', 7', 8', 10' and 14' options. Choose from standard or telescopic arm configurations to match the reach and airflow requirements of your welding application.


They provide high-performance welding fume filtration

FAF combines source capture with high-efficiency filtration to help remove welding fumes from the workplace. Filter options include MERV 15 nanofiber fire-retardant filters and HEPA filtration, allowing the system to be configured for a variety of welding and industrial applications.


They deliver powerful airflow at the source

FAF systems are designed to provide strong airflow directly at the fume arm hood. Our larger 8" systems can deliver approximately 1,400 CFM at the hood, helping capture welding fumes before they migrate into the worker's breathing zone or surrounding workspace.


They are in stock & ready to ship

We stock core IAP fume extraction products at our Tennessee warehouse, allowing many FAF configurations to ship quickly. Our dedicated sales team can help select the appropriate arm size, length, blower and filtration package for your application.


Not sure what you need?

Tell us what you're trying to capture → We'll help size the system and select the right products.


FAQ's

  • What is a fume arm filtration system?

    A fume arm filtration system combines a source-capture fume extraction arm, industrial fan and air filtration into one compact system. IAP's Fume Arm Filtration (FAF) units are designed to capture welding fumes and other airborne contaminants at the source and filter them without requiring a large centralized dust collector.

  • What applications are fume arm filtration systems used for?

    Fume arm filtration systems are commonly used for welding, grinding, soldering, maintenance work and other processes that generate smoke, fumes or fine particulate. They are particularly useful in welding schools, technical colleges, small manufacturing facilities, maintenance shops and other applications where dedicated source capture is needed at individual workstations.

  • Are fume arm filtration systems good for welding fume extraction?

    Yes. Fume arm filtration systems are designed specifically for source capture, allowing the extraction hood to be positioned close to the welding process. Capturing welding fumes at the source helps prevent contaminants from spreading throughout the work area and provides a compact alternative to larger centralized welding fume collection systems.

  • What is the difference between a fume arm and a fume arm filtration system?

    A fume arm captures and transports contaminated air, but it requires a separate fan and filtration or exhaust system. A fume arm filtration system combines the extraction arm, fan and filter into one complete package. This makes a FAF unit a convenient option when a standalone source-capture system is needed without designing a larger ducted system.

  • What filter does the IAP fume arm filtration system use?

    Standard IAP Fume Arm Filtration units use a fire-retardant nanofiber MERV 15 filter. The system also includes an 18-inch reverse-flow disposable filter and HEPA filtration is available as an option. Filter selection should be based on the specific contaminant and application rather than airflow alone.

  • Are fume arm filtration systems good for welding or trade schools?

    Yes. FAF systems are particularly well suited for welding schools, high school CTE programs, technical colleges and other training facilities. Their compact design provides dedicated source capture at individual welding stations without requiring a large centralized filtration system. FAF units can also be integrated with WeldShell welding booths to create complete welding workstations.

  • What size fume arm filtration system do I need?

    The appropriate FAF system depends on the required capture area, application, arm length, airflow and available space. IAP offers FAF systems with 4-inch, 6-inch and 8-inch extraction arms in several lengths, with fan sizes ranging from 1 HP to 2 HP on the standard models. IAP can help select the appropriate configuration for your application.

  • How many welding stations can a fume arm filtration system serve?

    A standard FAF unit is designed around a dedicated source-capture arm, but larger systems and custom configurations can be designed to serve multiple workstations. IAP can also configure dual-arm filtration systems or combine multiple extraction arms and fans with ductwork when a project requires several welding stations. The appropriate configuration depends on simultaneous use and required airflow.

  • Do I need a centralized dust collector for welding fume extraction?

    Not necessarily. A centralized dust collector can be appropriate for large facilities with many permanent welding stations, but individual fume arm filtration units can be a practical alternative for smaller shops, welding labs and facilities where a centralized duct system is unnecessary. IAP can help determine whether individual FAF units, a multi-arm system, or a centralized system is appropriate for your facility.

  • Can I use a HEPA filter with a fume arm filtration system?

    Yes. IAP offers optional HEPA filter configurations for its Fume Arm Filtration systems. HEPA filtration can be appropriate for applications requiring higher-efficiency particulate filtration, but the correct filtration should be selected based on the contaminants being generated and the requirements of the application.

Other Products